Chapter 5 Troubleshooting
SuperLoader Error Logs
SuperLoader User’s Guide 163
AA Picker Cartridge
Sensor Error
Perform calibration and confirm calibration is
successful.
Run the Health test.
If the problem prevents the test from running, contact
Quantum Customer Support and/or replace the
chassis/picker assembly.
AB Drive Path Sensor
Error
Run the Health test.
Power cycle the SuperLoader.
If all previous steps fail, contact Quantum Customer
Support and/or replace the chassis/picker assembly.
AC Mail Slot Door Sensor
Error
Insert a cartridge into the SuperLoader via the mail slot.
Power cycle the SuperLoader.
If all previous steps fail, contact Quantum Customer
Support and/or replace the chassis/picker assembly.
AD Mail Slot Solenoid
Error
Insert a cartridge into the SuperLoader via the mail slot.
Power cycle the SuperLoader.
If all previous steps fail, contact Quantum Customer
Support and/or replace the chassis/picker assembly.
AE Unknown Servo Error
Run the Health test.
If all previous steps fail, contact Quantum Customer
Support and/or replace the DCA and/or the chassis/
picker assembly.
AF Error Log Information
Event
No action required.
B0-BF Error Events related to
the picker not rotating
or translating correctly.
Run the Health test.
Power cycle the SuperLoader.
If all previous steps fail, contact Quantum Customer
Support and/or replace the chassis/picker assembly.
Error Description Suggested Actions