DISPlay Subsystem (Analog Demodulation, K7) R&S FSL
1300.2519.12 6.296 E-11
D
ISPlay[:WINDow<1|2>]:TRACe<1...6>:Y[:SCALe]:RPOSition
Characteristics
*RST value:
100 PCT AF spectrum display of AM, FM, or PM
50 PCT AM, FM, or PM display
For further details refer to "DISPlay[:WINDow<1|2>]:TRACe<1...6>:Y[:SCALe]:RPOSition
(models with tracking generator)" on page 6.136.
DISPlay[:WINDow<1|2>]:TRACe<1...6>:Y[:SCALe]:RVALue
This command defines the reference value assigned to the reference position. Separate
reference values are maintained for the various displays.
Example
DISP:TRAC:Y:RVAL 0
Sets the value assigned to the reference position to 0 Hz (analog demodulation)
Characteristics
*RST value:
0 PCT AM display
0 Hz FM display
0 rad PM display
100 PCT AF spectrum display of AM signal
250 kHz AF spectrum display of FM signal
10 rad AF spectrum display of PM signal
For further details refer to "DISPlay[:WINDow<1|2>]:TRACe<1...6>:Y[:SCALe]:RPOSition
(models with tracking generator)" on page 6.136.
DISPlay[:WINDow<1|2>]:TRACe<1...6>:Y:SPACing
When the AF spectrum result display is selected, only the parameters LINear and LOGarithmic
are allowed.
For further details refer to "DISPlay[:WINDow<1|2>]:TRACe<1...6>:Y:SPACing" on page 6.134.