R&S FSL SENSe Subsystem (Analog Demodulation, K7)
1300.2519.12 6.303 E-11
[
SENSe:]ADEMod:AF:SPAN:FULL
This command sets the maximum span for AF spectrum result display.
T
he maximum span corresponds to half the measurement bandwidth of analog demodulation
([SENSe:]ADEMod:BANDwidth|BWIDth:DEModulation).
Example
ADEM ON
Switches on the analog demodulator
CALC:FEED 'XTIM:FM:AFSP'
Switches on AF spectrum result display of FM
ADEM:BAND 5 MHz
Sets the measurement bandwidth to 5 MHz
ADEM:AF:SPAN:FULL
Sets the AF span to 2.5 MHz
Characteristics
*RST value: –
SCPI: device–specific
Mode
ADEMOD
[SENSe:]ADEMod:AF:STARt
This command sets the start frequency for AF spectrum result display.
Parameter
<numeric_value>
Example
ADEM ON
Switches on analog demodulator
CALC:FEED 'XTIM:FM:AFSP'
Switches on AF spectrum result display of FM
ADEM:BAND 5 MHz
Sets the measurement bandwidth to 5 MHz
ADEM:AF:STAR 0kHz
Sets the AF start frequency to 0 kHz
ADEM:AF:STOP 500kHz
Sets the AF stop frequency to 500 kHz
Characteristics
*RST value: 0 MHz
SCPI: device–specific
Mode
ADEMOD