CALCulate Subsystem (CATV, K20) R&S FSL
1300.2519.12 6.456 E-11
CALC:DTV:LIM:RES:MERR:UPP?
Performs an upper limit check for the root mean square value of the modulation error rate.
Characteristics
RST value: –
SCPI: device–specific
Mode
CATV
CALCulate:DTV:LIMit:RESult:PJITter[:UPPer]?
This command performs an upper limit check for the phase jitter in the Modulation Errors
measurement.
This command is a query and therefore has no *RST value.
Example
CALC:DTV:LIM:PJIT 1
Sets the upper limit for the phase jitter to 1 deg.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:DTV:LIM:RES:PJIT?
Performs an upper limit check for the phase jitter.
Characteristics
RST value: –
SCPI: device–specific
Mode
CATV
CALCulate:DTV:LIMit:RESult:QERRor:LOWer?
This command performs a lower limit check for the quadrature error in the Modulation Errors
measurement.
This command is a query and therefore has no *RST value.
Example
CALC:DTV:LIM:QERR:LOW 10
Sets the lower limit for the quadrature error to 10 deg.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:DTV:LIM:RES:QERR:LOW?
Performs a lower limit check for the quadrature error.
Characteristics
RST value: –
SCPI: device–specific
Mode
CATV