SENSe Subsystem (WCDMA, K72) R&S FSL
1300.2519.12 6.584 E-11
[SENSe<1|2>:]CDPower:ASEQuence
This command starts the following sequence:
Adjusts the reference level.
Searches automatically the scrambling code that leads to the highest signal power and stores it
as new scrambling code.
Changes into the Result Summary result display.
The numeric suffixes <1|2> are irrelevant for this command.
This command is an event and therefore has no *RST value and no query.
Example
CDP:ASEQ
Characteristics
RST value:
SCPI: device–specific
Mode
WCDMA
[SENSe<1|2>:]CDPower:CODE
This command sets the code number. The code number refers to code class 9 (spreading factor
512).
The numeric suffixes <1|2> are irrelevant for this command.
Parameter
0 to 511
Example
CDP:CODE 30
Sets code number 30.
Characteristics
RST value: 0
SCPI: device–specific
Mode
WCDMA
[SENSe<1|2>:]CDPower:HSDPamode
This command activates or deactivates the HSUPA/DPA channel detection.
The numeric suffixes <1|2> are irrelevant for this command.
Parameter
ON The high speed channels can be detected.
The modulation type (QPSK /16QAM) is detected.
OFF The high speed channel can not be detected.
Pilot symbols are detected.