Remote Commands of the CDMA2000 BTS Analyzer Option (K82) R&S FSL
1300.2519.12 6.600 E-11
Example
CALC:LIM:ESP:REST
Resets the limit lines for the Spectrum Emission Mask to the default setting.
Characteristics
RST value: -
SCPI: device-specific
Mode
CDMA
CALCulate<1|2>:LIMit<1...8>:ESPectrum:VALue
This command activates the manual limit line selection and specifies the expected power as a
value. Depending on the entered value, one of the predefined limit lines is selected.
The numeric suffix at CALCulate<1|2> specifies the measurement window. The numeric suffix
at LIMit<1...8> is irrelevant for this command.
Parameter
33
P
33
28
28
P < 33
0 P < 28
Example
INST:SEL BC2K
Activates the CDMA2000 BTS Analyzer option.
INIT:CONT OFF
Selects single sweep.
CONF:CDP:BCL 1
Select band class 1, 1900 MHz
CONF:CDP:MEAS ESP
Selects Spectrum Emission Mask measurement.
CALC:LIM:ESP:VAL 33
Activates manual selection of the limit line and selects the limit line for P
33.
INIT;*WAI
Starts measurement with synchronization.
CALC:LIM:FAIL?
Queries result of the limit check.
Characteristics
RST value: 0
SCPI: device-specific
Mode