R&S FSL SENSe Subsystem (CDMA, K82)
1300.2519.12 6.617 E-11
Characteristics
RST value: –60 dB
SCPI: device-specific
Mode
CDMA
[SENSe<1|2>:]CDPower:IQLength
This command sets the capture length in multiples of the power control group.
The numeric suffix at SENSe<1|2> is irrelevant for this command.
Parameter
2 to 12
Example
INST:SEL BC2K
Activates the CDMA2000 BTS Analyzer option.
INIT:CONT OFF
Selects single sweep.
CDP:IQL 8
Sets 8 PCGs as capture length.
INIT;*WAI
Starts measurement with synchronization.
Characteristics
RST value: 3
SCPI: device-specific
Mode
CDMA
[SENSe<1|2>:]CDPower:LEVel:ADJust
This command adjusts the reference level of the R&S FSL to the measured channel power. This
ensures that the settings of the RF attenuation and the reference level are optimally adjusted to
the signal level without overloading the R&S FSL or limiting the dynamic response by a too low
signal–to–noise ratio.The numeric suffix at SENSe<1|2> is irrelevant for this command.
This command is an event and therefore has no *RST value and no query.
Example
INST:SEL BC2K
Activates the CDMA2000 BTS Analyzer option.
INIT:CONT OFF
Selects single sweep.
CDP:LEV:ADJ
Starts automatic level setting.
INIT;*WAI
Starts measurement with synchronization.