Remote Commands of the CDMA2000 BTS Analyzer Option (K82) R&S FSL
1300.2519.12 6.618 E-11
C
haracteristics
RST value: -
SCPI: device-specific
M
ode
CDMA
[SENSe<1|2>:]CDPower:NORMalize
This command activates or deactivates the elimination of the IQ offset from the signal.
The numeric suffix at SENSe<1|2> is irrelevant for this command.
Parameter
ON | OFF
Example
INST:SEL BC2K
Activates the CDMA2000 BTS Analyzer option.
INIT:CONT OFF
Selects single sweep.
CDP:NORM ON
Eliminates the DC offset from the signal.
INIT;*WAI
Starts measurement with synchronization.
Characteristics
RST value: OFF
SCPI: device-specific
Mode
CDMA
[SENSe<1|2>:]CDPower:ORDer
This command sets the channel sorting for the Code Domain Power and Code Domain Error
result displays.
The numeric suffix at SENSe<1|2> is irrelevant for this command.
Parameter
HADamard | BITReverse
For further details refer to chapter 4, "Code Order".
Example
INST:SEL BC2K
Activates the CDMA2000 BTS Analyzer option.
INIT:CONT OFF
Selects single sweep.
INIT;*WAI
Starts measurement with synchronization.
CDP:ORD HAD
Sets Hadamard order.
TRAC? TRACE2
Reads out the results in Hadamard order.

Table of Contents