Remote Commands of the 1xEV-DO BTS Analyzer Option (K84) R&S FSL
1300.2519.12 6.648 E-11
CONFigure:CDPower[:BTS]:CTABle:RESTore
This command restores the predefined channel tables to their factory–set values. In this way,
you can undo unintentional overwriting.
This command is an event and therefore has no *RST value and no query.
Example
INST:SEL BC2K
Activates the 1XEV-DO BTS Analyzer option.
CONF:CDP:CTAB:REST
Restores the channel table.
Characteristics
RST value: -
SCPI: device-specific
Mode
EVDO
CONFigure:CDPower[:BTS]:CTABle:SELect
This command selects a predefined channel table.
Parameter
<'string'> = name of the channel table
Example
Refer to the example of the CONFigure:CDPower[:BTS]:MCARier[:STATe] command.
Characteristics
RST value: "RECENT"
SCPI: device-specific
Mode
EVDO
CONFigure:CDPower[:BTS]:BCLass
This command selects the band class to be used.
Parameter
0 800 MHz band
1 1900 MHz band
2 TACS band
3 JTACS band
4 Korean PCS band
5 450 MHz band
6 2 GHz band
7 700 MHz band
8 1800 MHz band
9 900 MHz band