R&S FSL DISPlay Subsystem (WLAN, K91 / K91n)
1300.2519.12 6.711 E-11
The numeric suffix at WINDow<1|2> must be 2 as the relevant results are always displayed in
s
creen B. The numeric suffix at TRACe<1...3> must be 1.
Parameter
<numeric_value>
Example
DISP:WIND2:TRAC:Y:SCAL:DPIV 2
Sets the Y scale division to size to 2.
Characteristics
*RST value: 3
Mode
WLAN
DISPlay[:WINDow<1|2>]:TRACe<1…3>:Y[:SCALe]:RLEVel
This remote control command can be used to set the current internal instrument reference level
used when performing measurements. The numeric suffix at WINDow<1|2> and TRACe<1...3>
are irrelevant.
Parameter
numeric value in dB
Example
DISP:TRAC:Y:RLEV?
returns the current reference level in use
Characteristics
*RST value: –
Mode
WLAN
DISPlay[:WINDow<1|2>]:TRACe<1…3>:Y[:SCALe]:RLEVel:OFFSet
For details refer to "DISPlay[:WINDow<1|2>]:TRACe<1...6>:Y[:SCALe]:RLEVel:OFFSet" on
page 6.135.