CONFigure Subsystem (WiMAX, K92/K93) R&S FSL
1300.2519.12 6.800 E-11
CONF:WIM:FBAN ETSI2
Configures the frequency band to be ETSI 10.0GHz – 10.68GHz.
CONF:WIM:FBAN?
After frequency band is set to ETSI2 this will return "ETSI2'' as the current frequency band.
INIT
Starts a Phase or Frequency vs Preamble measurement.
Characteristics
RST value:
SCPI: device–specific
Mode
OFDM, OFDMA/WiBro
CONFigure:WIMax:IGRatio
This command specifies the number of guard samples.
Parameter
valid range:
b
g
T
T
{1/32, 1/16, 1/8, 1/4}
The ration can be set to one of four values – 4, 8, 16 or 32. The table below shows the
relationship between these values and the number of guard samples.
Value Guard samples (T
g
/T
b
)
4 1/4
8 1/8
16 1/16
32 1/32
Example
CONF:WIM:IGR 16
Sets the number of guard samples to 1/16.
Characteristics
RST value:
SCPI: device–specific
Mode
OFDM, OFDMA/WiBro
CONFigure:WIMax:LMODe
This command specifies only to analyze the Down Link or Up Link bursts during a
measurement.
Parameter
UL | DL
Example
CONF:WIM:LMOD UL
Only the Up Link bursts are analyzed.

Table of Contents