SENSe Subsystem (WiMAX, K92/K93) R&S FSL
1300.2519.12 6.846 E-11
[SENSe:]SWEep:ACPR:TIME
This command specifies the sweep time for the Spectrum Mask and Spectrum ACP/ACPR
measurements.
Parameter
10 ms to 16000 s
Example
SWE:ACPR:TIME:AUTO OFF
Deactivates the automatic calculation of the sweep time.
SWE:ACPR:TIME 100S
Sets the sweep time to 100 s.
Characteristics
RST value: 2s
SCPI: conform
Mode
OFDM, OFDMA/WiBro
[SENSe:]SWEep:ACPR:TIME:AUTO
This command activates or deactivates the automatic calculation of the sweep time for the
Spectrum Mask and Spectrum ACP/ACPR measurements.
Parameter
ON | OFF
Example
SWE:ACPR:TIME:AUTO OFF
Deactivates the automatic calculation of the sweep time.
Characteristics
RST value: ON
SCPI: conform
Mode
OFDM, OFDMA/WiBro
[SENSe:]SWEep:COUNt
This command specifies the number of sweeps for Spectrum Mask and Spectrum ACPR
measurements.
Parameter
1 to 32767
Example
SWE:COUNt 64
Sets the number of sweeps to 64.
Characteristics
*RST value: 1
SCPI: conform
Mode
OFDM, OFDMA/WiBro