R&S FSL Analog Demodulation (Option K7)
1300.2519.12 4.155 E-11
Unit (PM AF result display)
For details refer to the Unit softkey in the amplitude menu of the base unit.
Input 50 D / 75 D
For details refer to the Input 50 D / 75 D softkey in the amplitude menu of the base unit.
Softkeys of the bandwidth menu (Analog Demodulation mode)
The following table shows all softkeys available in the bandwidth menu in Analog Demodulation mode
(BW key). It is possible that your instrument configuration does not provide all softkeys. If a softkey is
only available with a special option, model or (measurement) mode, this information is delivered in the
corresponding softkey description.
Command
Res BW
Demod BW
Meas Time
Res BW (span > 0)
Opens an edit dialog box to enter a value for the resolution bandwidth. The range is specified in
the data sheet.
Remote: ADEM:SPEC:BAND 10 kHz
Demod BW
For details refer to the Demod BW softkey in the in the analog demodulation menu.
Meas Time
For details refer to the Meas Time softkey in the in the analog demodulation menu.
Softkeys of the sweep menu (Analog Demodulation mode)
The following table shows all softkeys available in the sweep menu in Analog Demodulation mode
(SWEEP key). It is possible that your instrument configuration does not provide all softkeys. If a softkey
is only available with a special option, model or (measurement) mode, this information is delivered in
the corresponding softkey description.
Command
Continuous Sweep
Single Sweep
Continue Sgl Sweep
Meas Time
Sweep Count

Table of Contents