Bluetooth Measurements (Option K8) R&S FSL
1300.2519.12 4.170 E-11
Burst Offset
Opens an edit dialog box to define the time to be displayed before the identified burst. The
values range from –10 ms to + 10 ms, with negative values moving the burst to the left, positive
values to the right. The default setting for the burst offset is 0.
If the burst is identified, but the selected measurement time cannot be displayed due to the
selected burst offset, the message BURST OFFSET INVALID is displayed.
This softkey is only available if the Find Sync On/Off softkey is deactivated and the Find Burst
On/Off softkey is activated.
Access
C
ode
Meas Time (User)
Burst Offset > 0
Burst Offset = 0
Burst Offset < 0
Search Length
Burst
Header Payload
Meas Time (User)
Meas Time (User)
T
rigger (optional)
Remote: DDEM:SEAR:PULS:OFFS 1MS
Search Len Auto
Activates or deactivates the automatic selection of the search length for the search of the sync
word or the burst, depending on the selected packet type. The automatic search length is
determined as follows:
Trigger free run:
search length = 3 * packet length + | sync offset or burst offset |
All other trigger modes:
search length = 1 * packet length + 1 Slot + | sync offset or burst offset |
If the selected measurement time is higher than the packet length, the following difference is
added to the search length:
measurement time – packet length
In the default setting, the automatic calculation of the search length is activated.
Remote: DDEM:SEAR:TIME:AUTO OFF