R&S FSL 1xEV-DO BTS Analyzer (Option K84)
1300.2519.12 4.359 E-11
In order to provide a quick swap from the base unit to the 1xEV-DO0 BTS Analyzer option, some
p
arameters are passed on.
Transferred parameter
Reference Level
Ref Level Offset
RBW
VBW
# of Samples
Refer also to the Power softkey in the measurement menu.
Adjacent Channel Power
The Adjacent Channel Power measurement analyses the power of the TX channel and the power of
adjacent and alternate channels on the left and right side of the TX channel. The number of TX
channels and adjacent channels can be modified as well as the band class.
Beneath the measurement screen the bandwidth and power of the TX channel and the bandwidth,
spacing and power of the adjacent and alternate channels are displayed.
The default settings are in accordance with the 3GPP2 specifications.
Setting Default value
Adjacent Channel Power On
ACP Standard 1xEV-DO0 MC1
Number of adjacent channels 2
In order to provide a quick swap from the base unit to the 1xEV-DO BTS Analyzer option, some
parameters are passed on.
Transferred parameter
Reference Level
Ref Level Offset
RBW
VBW
# of Adjacent Channels
Sweep Time
Span
Fast ACP Mode
For details on the softkeys of the Adjacent Channel Power measurement refer to the Adjacent
Channel Power softkey in the measurement menu.