R&S FSL 1xEV-DO BTS Analyzer (Option K84)
1300.2519.12 4.407 E-11
Power vs Time
Starts the measurement of the Power vs Time. This measurement is required by the standard
for the Emission Envelope Mask.
For details on screen layout and default values see the description of the Power vs Time.
Also opens the PvT submenu containing the following softkeys:
Command
No of HalfSlots
RF:Slot Full Idle
Burst Fit On Off
Reference Mean Pwr
Reference Manual
Set Mean To Manual
Restart On Fail
Restore STD Lines
Remote: CONF:CDP:MEAS PVT
No of HalfSlots
Change the number of halfslots for averaging. The default value is 100.
Remote: SWE:COUN <numeric value>
RF:Slot Full Idle
Defines the expected signal. Set it to either FULL or IDLE mode. The limit lines and the borders
for calculating the mean power are set. The lower and upper limit line are called DOPVTFL/
DOPVTFU for FULL and DOPVTIL/ DOPVTIU for IDLE mode. It is possible to change these
lines with the standard limit line editor.
Remote: CONF:CDP:RFS FULL
Burst Fit On Off
Activate an automatic burst alignment to the center of the diagram. If active the burst fit
algorithm searches the maximum and minimum gradient, between them the maximum peak is
determined, and from this point the 7 dB down points are searched. If these are within plausible
ranges the burst is centered in the screen, otherwise nothing will happen. The default setting is
OFF.
The softkey is only available if the RF:Slot is set to idle mode (see RF:Slot Full Idle).
Remote: CONF:CDP:PVT:BURS ON