CALCulate Subsystem R&S FSL
1300.2519.12 6.26 E-11
CALCulate:FLINe Subsystem
The CALCulate:FLINe subsystem defines the position of the frequency lines.
Commands of the CALCulate:FLINe Subsystem
– CALCulate<1|2>:FLINe<1|2>
– CALCulate<1|2>:FLINe<1|2>:STATe
CALCulate<1|2>:FLINe<1|2>
This command defines the position of the frequency lines that mark the frequencies.
The numeric suffixes <1|2> are irrelevant for this command.
Parameter
0 to f
max
Example
CALC:FLIN2 120MHz
Characteristics
*RST value: – (STATe to OFF)
SCPI: device–specific
Mode
A–F
CALCulate<1|2>:FLINe<1|2>:STATe
This command switches the frequency line on or off.
The numeric suffixes <1|2> are irrelevant for this command.
Parameter
ON | OFF
Example
CALC:FLIN2:STAT ON
Characteristics
*RST value: OFF
SCPI: device–specific
Mode
A–F