CALCulate Subsystem R&S FSL
1300.2519.12 6.52 E-11
C
ALCulate<1|2>:LIMit<1...8>:UPPer:MARGin
This command defines a margin to an upper limit line, at which out–of–limit values are signaled
(if the limit check is active), but not handled as a violation of the limit value.
Only the unit dB is available in spectrum analyzer mode.
The numeric suffixes <1|2> are irrelevant for this command.
This command is available from firmware version 1.10.
Parameter
<numeric_value>
Example
CALC:LIM2:UPP:MARG 10dB
Defines the margin of limit line 2 to 10 dB below the limit value.
Characteristics
*RST value: 0
SCPI: device–specific
Mode
A, ADEMOD, CDMA, EVDO
CALCulate<1|2>:LIMit<1...8>:UPPer:MODE
This command selects the relative or absolute scaling for the y–axis of the selected upper limit
line.
Selecting RELative causes the unit to be switched to DB.
The numeric suffixes <1|2> are irrelevant for this command.
This command is available from firmware version 1.10.
Parameter
RELative | ABSolute
Example
CALC:LIM2:UPP:MODE REL
Defines the y–axis of limit line 2 as relative scaled.
Characteristics
*RST value: ABSolute
SCPI: device–specific
Mode
A, ADEMOD, CDMA, EVDO
CALCulate<1|2>:LIMit<1...8>:UPPer:OFFSet
This command defines an offset for the y–axis of the selected relative upper limit line. In
contrast to CALCulate<1|2>:LIMit<1...8>:UPPer:SHIFt, the line is not shifted by
modifying the individual Y values but by means of an additive offset.
Only the unit dB is available in the spectrum analyzer mode.
The numeric suffixes <1|2> are irrelevant for this command.
This command is available from firmware version 1.10.