R&S FSL SENSe Subsystem
1300.2519.12 6.201 E-11
[
SENSe<1|2>:]FREQuency:CENTer:STEP
This command defines the step size of the center frequency.
T
he numeric suffixes <1|2> are not relevant.
Parameter
0 to f
max
Example
FREQ:CENT:STEP 120MHz
Characteristics
*RST value: – (AUTO 0.1 × SPAN is switched on)
SCPI: conform
Mode
all
[SENSe<1|2>:]FREQuency:CENTer:STEP:AUTO
This command couples the step size of the center frequency to the span (ON) or sets the value
of the center frequency entered via [SENSe<1|2>:]FREQuency:CENTer:STEP (OFF).
The numeric suffixes <1|2> are not relevant.
Parameter
ON | OFF
Example
FREQ:CENT:STEP:AUTO ON
Activates the coupling of the step size to the span.
Characteristics
*RST value: ON
SCPI: device–specific
Mode
all
[SENSe<1|2>:]FREQuency:CENTer:STEP:LINK
This command couples the step size of the center frequency to span (span >0) or to the
resolution bandwidth (span = 0) or cancels the couplings.
The numeric suffixes <1|2> are not relevant.
Parameter
SPAN coupling to frequency display range (for span > 0)
RBW coupling to resolution bandwidth (for span = 0)
OFF manual input, no coupling
Example
FREQ:CENT:STEP:LINK SPAN