To learn more, see "Issuing the HALT Command Before Removing Power" on the
facing page.
4.1.3 Issuing the HALT Command Before Removing Power
Gracefully shutting down SecureSync by using the HALT command offers the fol-
lowing advantages over shutting the unit down by interrupting the power supply:
The shutdown process will be logged
The System Clock will update the Real Time Clock with the latest System
Time.
SecureSync's file system will be synchronized, which under some cir-
cumstances will allow for faster startup next time the unit will be powered
up.
The HALT command may be issued to the SecureSync via:
the WebUI
the front panel keypad
the front panel serial port.
Note: Wait 30 seconds after entering the HALT command before
removing power.
Once the HALTprocess has been initiated, the front panel display will show halt-
ing and the time display will stop incrementing.
Issuing a HALT Command via the Web UI
1.
Navigate to TOOLS > SYSTEM: Reboot/Halt.
2.
The Reboot/Halt window will display. Select the Shutdown the Unit check-
box.