IPv4 Gateway: The gateway (default router) address is needed if
communication to the SecureSync is made outside of the local net-
work. By default, the gateway is disabled.
IPv6 Auto Configuration: Choose between Disabled (disable auto
configuration), Auto (stateless auto configuration using SLAAC and
DHCP), and Stateful (auto configuration using DHCP only).
Domain: This is the domain name to be associated with this port.
DNS Primary: This is the primary DNS address to be used for this
port. Depending on how your DHCP server is configured, this is set
automatically once DHCP is enabled. Alternatively, you may con-
figure your DHCP server to NOT use a DNS address. When DHCP is
disabled, DNS Primary is set manually, using the format "#.#.#.#" with
no leading zeroes or spaces, where each ‘#’ is a decimal integer from
the range [0,255].
DNS Secondary: This is the secondary DNS address to be used for
this port. Depending on how your DHCP server is configured, this is
set automatically once DHCP is enabled, or your DHCP server may be
configured NOT to set a DNS address. When DHCP is disabled, DNS
Secondary is set manually, using the format #.#.#.#” with no leading
zeroes or spaces, where each ‘#’ is a decimal integer from the range
[0,255].
MTU: Maximum Transmission Unit. Range (for Ethernetv2): Default:
1500 bytes. Smaller packages are recommended, if encapsulation is
required e.g., to meet encryption needs, which would cause the max-
imum package size to be exceeded. If the MTU is programmed out-
side of the default, SecureSync will automatically round up any entry
into the nearest multiple of 64 to follow Linux requirements.
Edit IPv6 Address: Click on this button to configure a static IPv6
address.
4.
To apply your changes, click Submit (the window will close), or Apply.
2.14.3 Network Services
Several standard network services can be enabled or disabled via the easily
accessible Network Services Panel under MANAGEMENT > Network Setup:
The Network Services panel has ON/OFF toggle switches for the following dae-
mons and features:
System Time Message: A once-per second Time Message sent out via Mult-
icast; for details, see "System Time Message" on page111.