EasyManua.ls Logo

Safran SecureSync 2400 - Format BBC-04

Safran SecureSync 2400
633 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G = System Good
D = Failure of SecureSync internal diagnostics
T = SecureSync does not have correct time
‘l command
The loopback command will cause SecureSyncto echo the next character
received back to the caller. This may be used by a caller’s equipment to calculate
the round trip delay across the PSTN connection in order to apply a correction to
the received time data.
Input format: l<CR>
Output format: (Next character received)
‘hu command
The hang up command will cause SecureSync to drop the line immediately and
terminate the call.
Input format: hu<CR>
5.4.14.4 Format BBC-04
This format is a string of ASCII characters and is sent once per second.
Number of characters: 18 (including CRLF)
E x a m p l e m e s s a g e :
T:ho:mi:sc:dw:da:mo:ye:lp:cs<CR><LF>
Where:
T Indicates the synchronous moment for the
time setting.
ho Hours (00-23)
mi Minutes (00-59)
sc Seconds (00-59)
dw Day of week (01=Monday to 7=Sunday)
582 SecureSync 2400 User Manual
APPENDIX

Table of Contents

Other manuals for Safran SecureSync 2400

Related product manuals