Max Poll Interval
Symmetric Key
Enable Burst [checkbox]
Enable Iburst [checkbox]
Mark ad Preferred [checkbox]
In the Peers tab:
View a list of configured peers and click Edit Peers to add or edit them.
In the NTP Peers window, click on the plus sign to add additional servers by
entering information into the following fields:
Host
Min Poll Interval
Max Poll Interval
Symmetric Key
Enable Burst [checkbox]
Enable Iburst [checkbox]
Mark ad Preferred [checkbox]
5.2.6.2 PTP Grandmaster [1204-32]
Note: These instructions refer only to the PTP available directly
through an installed 1204-32 Grandmaster PTP option card.
The on-unit PTP has different specifications. See "Configuring PTP"
on page149 for more information.
Precision Time Protocol (PTP) is a protocol that can be used to synchronize com-
puters on an Ethernet network. The Precision Time Protocol (PTP) option module
supports PTP Version 2, as specified in the IEEE 1588-2008 standard (PTP Ver-
sion 1 is not supported), via one (1) Ethernet port.
The PTP option module implements a PTP Ordinary Clock that can be configured
to run as a Master Clock only. It transmits PTP packets via the Ethernet port, with
SecureSync 2400 User Manual 499