Note: SecureSync starts numbering I/O ports with 0 (only 1PPS and
10MHz outputs start at1, because of the built-in outputs).
The fields available are:
Signature Control: Used to control when the 1PPS output signal will be
present. See: "Signature Control" on page183.
Offset: Used to account for 1PPS cable delays or other latencies in the 1PPS
output. The Offset value is entered and displayed in nanoseconds (ns). The
available Offset range is -500 to +500ms.
Edge: The operator can select if the output signal is a positive (reference on
the rising edge) or a negative (reference on the falling edge) pulse.
Pulse Width: Configures the Pulse Width of the 1PPS output. The Pulse
Width is entered and displayed in nanoseconds (ns). The default Pulse
Width is 200 milliseconds.
1PPS Output: Status Window
To view the current settings of a 1PPS output, go to its Status window. For
instructions, see: "Viewing Input/Output Configuration Settings" on page363.
The Web UI list entries for these cards are:
1PPS In/Out
1PPS In/Out, Fiber
The connector numbers are:
J2, J3, J4 (model -28)
J2, J3 (model -2A)
SecureSync 2400 User Manual 393
APPENDIX