SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
223
2 Parameters
2.2 List of parameters
Description: Sets the scaling for the acceleration pre-control of the speed/velocity controller.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p0341, p0342
Warning: The acceleration precontrol r1518 is kept at the old value if the ramp-function generator tracking (r1199.5) is active or
the ramp-function generator output is set (r1199.3). This is used to avoid torque peaks. Depending on the application,
it may therefore be necessary to disable the ramp-function generator tracking (p1145 = 0) or the acceleration
precontrol (p1496 = 0).
The acceleration precontrol is set to zero, if the Vdc control is active (r0056.14/15).
Note: The parameter is set to 100% by the rotating measurement (refer to p1960).
The acceleration pre-control may not be used if the speed setpoint manifests significant ripple (e.g. analog setpoint)
and the rounding-off in the speed ramp-function generator is disabled.
We also recommend that the pre-control mode is not used if there is gearbox backlash.
Description: Sets the load moment of inertia.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note: (p0341 * p0342) + p1498 influence the speed/torque pre-control in encoderless operation.
Description: Sets the scaling for the acceleration integrator at low speeds (only for encoderless torque control).
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1), "Dynamic Drive Control" (DDC, p0096
= 2)
Refer to: p0341, p0342
Description: Sets the source for the torque setpoint.
For single-digit values, the following applies:
The value specifies the main setpoint.
For double-digit values, the following applies:
The left-hand digit specifies the supplementary setpoint, the right-hand digit the main setpoint.
p1496[0...n] Acceleration pre-control scaling / a_prectrl scal
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 6020, 6031
Min Max Factory setting
0.0 [%] 10000.0 [%] 0.0 [%]
p1498[0...n] Load moment of inertia / Load M_inertia
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: 25_1 Unit selection: p0100 Func. diagram: 6031
Min Max Factory setting
0.00000 [kgm²] 100000.00000 [kgm²] 0.00000 [kgm²]
p1499[0...n] Accelerating for torque control scaling / a for M_ctrl scal
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 6030
Min Max Factory setting
0.0 [%] 400.0 [%] 100.0 [%]
p1500[0...n] Torque setpoint selection / M_set sel
CU240B-2
CU240B-2_DP
Access level: 2 Calculated: - Data type: Integer16
Can be changed: C(1), T Scaling: - Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 66 0

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals