2 Parameters
2.2 List of parameters
Description: Sets the signal source of the switch setting I of instance NSW 0 of the numeric changeover switch.
Description: Display parameter for output quantity Y of instance NSW 0 of the numeric changeover switch.
Description: Setting parameter for the run-time group in which the instance NSW 0 of the numeric changeover switch is to be
called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NSW 0 within the run-time group set in p20221.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 1 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
p20219 BI: NSW 0 switch setting I / NSW 0 sw_setting
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
r20220 CO: NSW 0 output Y / NSW 0 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - -
p20221 NSW 0 run-time group / NSW 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
5 9999 9999
p20222 NSW 0 run sequence / NSW 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
0 32000 610
p20223[0...1] CI: NSW 1 inputs / NSW 1 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals