2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
516 List Manual (LH11), 01/2016, A5E33839529
Description: Setting parameter for the run-time group in which the instance NCM 1 of the numeric comparator is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NCM 1 within the run-time group set in p20322.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for set input S and reset input R of instance RSR 2 of the RS flipflop.
Index: [0] = Set S
[1] = Reset R
Description: Display parameter for output Q of instance RSR 2 of the RS flipflop
Description: Display parameter for inverted output QN of instance RSR 2 of the RS flipflop.
p20322 NCM 1 run-time group / NCM 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
5 9999 9999
p20323 NCM 1 run sequence / NCM 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7225
Min Max Factory setting
0 32000 830
p20324[0...1] BI: RSR 2 inputs / RSR 2 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - 0
r20325 BO: RSR 2 output Q / RSR 2 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -
r20326 BO: RSR 2 inverted output QN / RSR 2 inv outp QN
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals