SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
573
3 Function diagrams
3.3 Input/output terminals
Fig. 3-10 2242 – CU240E-2: Digital outputs (DO 0 ... DO 2)
- 2242 -
Function diagram
87654321
fp_2242_97_02.vsd
Input/Output Terminals
G120 CU240E-2
09.12.2015 V4.7.6
CU240E-2: Digital outputs (DO 0 … DO 2)
(52.3)
CU S_src DO 0
p0730
(52.7)
CU S_src DO 1
p0731
(52.2)
CU S_src DO 2
p0732
CU DO inv
p0748
CU DO inv
p0748
CU DO inv
p0748
Kl. = TerminalSampling time of the DI: 2 ms
CU DO status
r0747
CU DO status
r0747
CU DO status
r0747
.0
1
0
24 V
0 V
0 V
NO
COM
NC
Kl. 20
Kl. 19
Kl. 18
DO 0
Kl. 22
Kl. 21
DO 1
NO
NO
COM
NC
Kl. 25
Kl. 24
Kl. 23
DO 2
.2
.1
1
0
1
1
0
1
1
0
1