2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
472 List Manual (LH11), 01/2016, A5E33839529
Description: Display parameter for the inverted output of instance NOT 0 of the inverter.
Description: Setting parameter for the run-time group in which the instance NOT 0 of the inverter is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NOT 0 within the run-time group set in p20080.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity I of instance NOT 1 of the inverter.
Description: Display parameter for the inverted output of instance NOT 1 of the inverter.
r20079 BO: NOT 0 inverted output / NOT 0 inv output
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - -
p20080 NOT 0 run-time group / NOT 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
1 9999 9999
p20081 NOT 0 run sequence / NOT 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
0 32000 160
p20082 BI: NOT 1 input I / NOT 1 input I
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - 0
r20083 BO: NOT 1 inverted output / NOT 1 inv output
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - -

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals