SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
511
2 Parameters
2.2 List of parameters
Description: Sets the differentiating time constant Td in milliseconds of instance DIF 0 of the differentiating element.
Description: Display parameter for output quantity Y of instance DIF 0 of the differentiating element.
Description: Setting parameter for the run-time group in which instance DIF 0 of the differentiating element is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance DIF 0 within the run-time group set in p20287.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity I of instance NOT 4 of the inverter.
Description: Display parameter for the inverted output of instance NOT 4 of the inverter.
p20285 DIF 0 differentiating time constant in ms / DIF 0 T_diff ms
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
0.00 340.28235E36 0.00
r20286 CO: DIF 0 output Y / DIF 0 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - -
p20287 DIF 0 run-time group / DIF 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
5 9999 9999
p20288 DIF 0 run sequence / DIF 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
0 32000 750
p20300 BI: NOT 4 input I / NOT 4 input I
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - 0
r20301 BO: NOT 4 inverted output / NOT 4 inv output
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - -