EasyManuals Logo

Siemens CU240B-2 List Manual

Siemens CU240B-2
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #500 background imageLoading...
Page #500 background image
2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
500 List Manual (LH11), 01/2016, A5E33839529
Description: Sets the signal source of the switch setting I of instance NSW 1 of the numeric changeover switch.
Description: Display parameter for output quantity Y of instance NSW 1 of the numeric changeover switch.
Description: Setting parameter for the run-time group in which the instance NSW 1 of the numeric changeover switch is to be
called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NSW 1 within the run-time group set in p20226.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance LIM 0 of the limiter.
p20224 BI: NSW 1 switch setting I / NSW 1 sw_setting
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
r20225 CO: NSW 1 output Y / NSW 1 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - -
p20226 NSW 1 run-time group / NSW 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
5 9999 9999
p20227 NSW 1 run sequence / NSW 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
0 32000 620
p20228 CI: LIM 0 input X / LIM 0 input X
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7260
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals