EasyManua.ls Logo

Siemens CU240B-2 - p2150[0...n] Hysteresis speed 3; n_hysteresis 3; p2151[0...n] CI: Speed setpoint for messages;signals; n_set for msg; p2152[0...n] Delay for comparison n > n_max; Del n > n_max; p2153[0...n] Speed actual value filter time constant; n_act_filt T

Siemens CU240B-2
924 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
309
2 Parameters
2.2 List of parameters
Description: Sets the hysteresis speed (bandwidth) for the following signals:
"|n_act| < speed threshold value 3" (BO: r2199.0)
"n_set >= 0" (BO: r2198.5)
"n_act >= 0" (BO: r2197.3)
Dependency: Refer to: p2161, r2197, r2199
Description: Sets the signal source for the speed setpoint for the following messages:
"Speed setpoint - actual value deviation within tolerance t_off" (BO: r2197.7)
"Ramp-up/ramp-down completed" (BO: r2199.5)
"|n_set| < p2161" (BO: r2198.4)
"n_set > 0" (BO: r2198.5)
Dependency: Refer to: r2197, r2198, r2199
Description: Sets the delay time for comparing the speed with the maximum speed.
Dependency: Refer to: p1082, r1084, r1087, p2162
Description: Sets the time constant of the PT1 element to smooth the speed / velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages and
signals.
Dependency: Refer to: r2169
p2150[0...n] Hysteresis speed 3 / n_hysteresis 3
Access level: 3 Calculated: p0340 = 1,3,5 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: 3_1 Unit selection: p0505 Func. diagram: 8010, 8011, 8022
Min Max Factory setting
0.00 [rpm] 300.00 [rpm] 2.00 [rpm]
p2151[0...n] CI: Speed setpoint for messages/signals / n_set for msg
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2000 Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 8011
Min Max Factory setting
- - 1170[0]
p2152[0...n] Delay for comparison n > n_max / Del n > n_max
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 8023
Min Max Factory setting
0 [ms] 10000 [ms] 200 [ms]
p2153[0...n] Speed actual value filter time constant / n_act_filt T
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: 8010
Min Max Factory setting
0 [ms] 1000000 [ms] 0 [ms]

Table of Contents

Other manuals for Siemens CU240B-2

Related product manuals