SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
539
2 Parameters
2.3 Parameters for data sets
p0826[0...n] Motor changeover motor number / Mot_chng mot No.
p1231[0...n] DC braking configuration / DCBRK config
p1232[0...n] DC braking braking current / DCBRK I_brake
p1233[0...n] DC braking time / DCBRK time
p1234[0...n] Speed at the start of DC braking / DCBRK n_start
p1909[0...n] Motor data identification control word / MotID STW
p1980[0...n] PolID technique / PolID technique
p1999[0...n] Ang. commutation offset calibr. and PollD scaling / Com_ang_offs scal
r3926[0...n] Voltage generation alternating base voltage amplitude / U_gen altern base
p5350[0...n] Mot_temp_mod 1/3 boost factor at standstill / Standst boost_fact
p5390[0...n] Mot_temp_mod 1/3 alarm threshold / A thresh
p5391[0...n] Mot_temp_mod 1/3 fault threshold / F thresh
r5398[0...n] Mot_temp_mod 3 alarm threshold image p5390 / A thr image p5390
r5399[0...n] Mot_temp_mod 3 fault threshold image p5391 / F thr image p5391
2.3.4 Power unit Data Sets (PDS)
Product: SINAMICS G120 CU240, Version: 4707900, Language: eng, Type: PDS
p0124[0...n] CU detection via LED / CU detection LED
r0200[0...n] Power unit code number actual / PU code no. act
p0201[0...n] Power unit code number / PU code no
r0203[0...n] Actual power unit type / PU actual type
r0204[0...n] Power unit hardware properties / PU HW property
2.3.5 Encoder Data Sets (EDS)
Product: SINAMICS G120 CU240, Version: 4707900, Language: eng, Type: EDS
p0422[0...n] Absolute encoder linear measuring step resolution / Enc abs meas step