SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
361
2 Parameters
2.2 List of parameters
Dependency: Refer to: r3925
Note: The parameter is a copy of p1909.
Description: Successfully completed component of the last rotating measurement carried out.
Dependency: Refer to: r3925
Note: The parameter is a copy of p1959.
Description: Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
21 Calibrating the output voltage measurement Yes No -
22 Only identify circle Yes No -
23 De-activate circle identification Yes No -
24 Circle identification with 0 and 90 degrees Yes No -
r3928[0...n] Rotating measurement configuration / Rot meas config
Access level: 3 Calculated: p0340 = 1 Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
01 Saturation characteristic identification Yes No -
02 Moment of inertia identification Yes No -
03 Re-calculates the speed controller
parameters
Yes No -
04 Speed controller optimization (vibration test) Yes No -
05 q leakage inductance ident. (for current
controller adaptation)
Yes No -
11 Do not change the controller parameters
during the measurement
Yes No -
12 Measurement shortened Yes No -
13 After measurement direct transition into
operation
Yes No -
14 Calculate speed actual value smoothing
time
Yes No -
r3929[0...n] Motor data identification modulated voltage generation / MotID U_gen mod
Access level: 4 Calculated: p0340 = 1 Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Wobble U_generate to determine dead-time
correction
Yes No -
01 Wobble U_generate to determine stator
resistance
Yes No -
02 Wobble U_generation to determine rotor
time constant
Yes No -
03 Wobble U_generation to determine leakage
inductance
Yes No -
04 Wobble U_generation to determine dynamic
leakage inductance
Yes No -
05 Wobble U_generation to determine
magnetizing inductance
Yes No -
08 Alternating U_generate to determine dead-
time correction
Yes No -
09 Alternating U_generate to determine stator
resistance
Yes No -
10 Alternating U_generate to determine rotor
time constant
Yes No -
11 Alternating U_generate to determine
leakage inductance
Yes No -

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals