3 Function diagrams
3.17 Free function blocks
SINAMICS G120 Control Units CU240B-2/CU240E-2
720 List Manual (LH11), 01/2016, A5E33839529
Fig. 3-143 7220 – ADD 0 ... 2, SUB 0 ... 1
- 7220 -
Function diagram
87654321
fp_7220_97_61.vsd
Free function blocks - Arithmetic function blocks
G120 CU240B/E-2
09.12.2015 V4.7.6
ADD 0 … 2, SUB 0 … 1
ADD 0
SUB 0
SUB 1
X1
X0
Y
ADD 0 RTG
5 ... 9999
p20096 (9999)
ADD 0 RunSeq
0 ... 32000
p20097 (210)
r20095
ADD 0 output Y
ADD 0 inputs
[0]
p20094
[1]
[2]
[3]
X2
X3
X2
X1
Y
SUB 0 RTG
5 ... 9999
p20104 (9999)
SUB 0 RunSeq
0 ... 32000
p20105 (240)
r20103
SUB 0 difference Y
X1 - X2
SUB 0 inputs
[0]
p20102
[1]
X1
X0
Y
ADD 1 RTG
5 ... 9999
p20100 (9999)
ADD 1 RunSeq
0 ... 32000
p20101 (220)
r20099
ADD 1 output Y
ADD 1 inputs
[0]
p20098
[1]
[2]
[3]
X2
X3
X2
X1
Y
SUB 1 RTG
5 ... 9999
p20108 (9999)
SUB 1 RunSeq
0 ... 32000
p20109 (250)
r20107
SUB 1 difference Y
SUB 1 inputs
[0]
p20106
[1]
ADD 1
X1
X0
Y
ADD 2 RTG
5 ... 9999
p20310 (9999)
ADD 2 RunSeq
0 ... 32000
p20311 (800)
r20309
ADD 2 output Y
ADD 2 inputs
[0]
p20308
[1]
[2]
[3]
X2
X3
ADD 2
+
+
+
X1 - X2
ADD (adder) SUB (subtracter)