2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
372 List Manual (LH11), 01/2016, A5E33839529
Note: Pe: PROFIenergy profiles
PROFIdrive state S4: operation
Description: Sets the mode-dependent properties for energy-saving.
Index: [0] = Reserved
[1] = Mode 2
Note: Pe: PROFIenergy profiles
Description: Display and binector output for the state display PROFIenergy energy saving active or inactive.
Note: Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
Description: Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibited".
Dependency: Refer to: r5613
Note: Pe: PROFIenergy profiles
Description: Displays the actual serial number of the Control Unit.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Inhibit PROFIenergy control commands Yes No -
01 Drive initiates OFF1 when transitioning to
energy-saving mode
Yes No -
02 Trans to energy-saving mode from
PROFIdrive state S3/S4 poss
Yes No -
p5612[0...1] Pe energy-saving properties mode-dependent / Pe properties mod
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - [0] 0110 bin
[1] 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Reserved Yes No -
r5613.0...1 CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2382
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Pe active Yes No -
01 Pe inactive Yes No -
p5614 BI: Pe set switching-on inhibited signal source / Pe sw on_inh s_src
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2382
Min Max Factory setting
- - 0
r7758[0...19] KHP Control Unit serial number / KHP CU ser_no
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -