2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
390 List Manual (LH11), 01/2016, A5E33839529
Description: Sets the enable signals for the safe motion monitoring.
Dependency: Refer to: p9501
Refer to: F01682, F01683
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
A change only becomes effective after a POWER ON.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description: Sets the enable signals for the safe motion monitoring.
Dependency: Refer to: p9501
Refer to: F01682, F01683
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
A change only becomes effective after a POWER ON.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description: Sets the function specification for the safe motion monitoring.
Value: 1: Safety without encoder and braking ramp(SBR)
3: Safety without encoder with accel_monitoring(SAM) / delay time
p9301 SI Motion enable safety functions (processor 2) / SI Mtn enable P2
CU240E-2_F Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 0000 0000 0000 0000 0000 0000
0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable SI Motion Enable Inhibit -
17 Enable SDI Enable Inhibit 2824
p9301 SI Motion enable safety functions (processor 2) / SI Mtn enable P2
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 0000 0000 0000 0000 0000 0000
0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable SI Motion Enable Inhibit -
16 Enable SSM hysteresis and filtering Enable Inhibit 2823
17 Enable SDI Enable Inhibit 2824
30 Enable F-DI in PROFIsafe telegram 900 Enable Inhibit -
p9306 SI Motion function specification (processor 2) / SI Mtn fct spec P2
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
1 3 1

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals