3 Function diagrams
3.10 Safety Integrated Extended Functions
SINAMICS G120 Control Units CU240B-2/CU240E-2
644 List Manual (LH11), 01/2016, A5E33839529
Fig. 3-74 2855 – Extended Functions via F-DI (p9601.2 = 1 and p9601.3 = 0)
- 2855 -
Function diagram
87654321
fp_2855_97_02.vsd
Safety Integrated Extended Functions
CU240E-2_F/DP_F
09.12.2015 V4.7.6
Extended Functions via F-DI (p9601.2 = 1 and p9601.3 = 0)
[2850.8]
F-DI 0
r9722.1
r9722.4
r9722.7
r9720.1
r9720.4
r9720.7
[2820.7], [2840.5]
SI Mtn integ STW
r9720
r9720
SI Mtn int stat P1
r9722
r9722
F-DI assignment
Statically active
Statically inactive
Deselection STO
Deselection SS1
Deselection SLS
Acknowledgment
SS1 active
STO active
SLS active
Internal event
Safe motion
monitoring
SI Motion
SI Mtn STO F-DI P1
0 ... 255
p10022 (0)
SI Mtn SS1 F-DI P1
0 ... 255
p10023 (0)
SI Mtn SLS F-DI P1
0 ... 255
p10026 (0)
SI Mtn ackn int P1
0 ... 255
p10006 (0)
[2820.1], [2840.1]
[2819.1], [2840.1]
[2819.1, [2840.1]]
[2850.8]
F-DI 1
[2850.8]
F-DI 2
SI SDI pos F-DI P1
0 ... 255
p10030 (0)
SI SDI neg F-DI P1
0 ... 255
p10031 (0)
SI SLS F-DI P2
0 ... 255
p10126 (0)
SI SS1 F-DI P2
0 ... 255
p10123 (0)
SI STO F-DI P2
0 ... 255
p10122 (0)
SI SDI pos F-DI P2
0 ... 255
p10130 (0)
SI SDI neg F-DI P2
0 ... 255
p10131 (0)
SI ackn int evt P2
0 ... 255
p10106 (0)
r9720.13
Deselection SDI negative
r9720.12
Deselection SDI positive
r9722.12
[2824.7], [2840.5]
SDI pos active
r9722.13
SDI neg active
r9722.15
SSM (n below limit)
[2819.7], [2840.5]
[2819.7], [2840.5]
[2840.1]
[2824.1], [2840.1]
[2824.1], [2840.1]
.0
.0
r9722.10
r9722.09
Active SLS stage, bit 0
Active SLS stage, bit 1
r9720.9
r9720.10
Select SLS bit 0
Select SLS bit 1
[2820.1], [2840.1]
[2820.1], [2840.1]
[2824.7], [2840.5]
[2824.7], [2840.5]
[2840.5]