2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
462 List Manual (LH11), 01/2016, A5E33839529
Description: Setting parameter for the run-time group in which the instance AND 0 of the AND function block is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance AND 0 within the run-time group set in p20032.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities I0, I1, I2, I3 of instance AND 1 of the AND function block.
Index: [0] = Input I0
[1] = Input I1
[2] = Input I2
[3] = Input I3
Description: Display parameter for binary quantity Q = I0 & I1 & I2 & I3 of instance AND 1 of the AND function block.
Description: Setting parameter for the run-time group in which the instance AND 1 of the AND function block is to be called.
p20032 AND 0 run-time group / AND 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7210
Min Max Factory setting
1 9999 9999
p20033 AND 0 run sequence / AND 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7210
Min Max Factory setting
0 32000 10
p20034[0...3] BI: AND 1 inputs / AND 1 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7210
Min Max Factory setting
- - 0
r20035 BO: AND 1 output Q / AND 1 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7210
Min Max Factory setting
- - -
p20036 AND 1 run-time group / AND 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7210
Min Max Factory setting
1 9999 9999

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals