SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
233
2 Parameters
2.2 List of parameters
The moment of inertia estimator is active above this threshold.
The value is referred to the rated torque (r0333).
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p1400, p1561, p1562
Note: The moment of inertia estimation is inaccurate at very low accelerating torques. As a consequence, below this
threshold, the estimator does not provide any new values.
Description: Sets the change time for the moment of inertia for the moment of inertia estimator.
Lower values mean that faster changes are possible.
For a higher value, this estimated value is smoothed more significantly.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p1400, p1560, p1562
Description: Sets the change time for the load torque for the moment of inertia estimator.
Lower values mean that faster changes are possible.
For a higher value, this estimated value is smoothed more significantly.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: p1400, p1560, p1561
Description: Display and connector output for the monitored load torque in the positive direction of rotation.
The moment of inertia estimator estimates the load torque drawn while the speed is constant.
Dependency: Refer to: p1400, p1560, p1561
Description: Display and connector output for the monitored load torque in the negative direction of rotation.
The moment of inertia estimator estimates the load torque drawn while the speed is constant.
Dependency: Refer to: p1400, p1560, p1561
p1561[0...n] Moment of inertia estimator change time moment of inertia / J_est t J
Access level: 3 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
10.00 [ms] 5000.00 [ms] 500.00 [ms]
p1562[0...n] Moment of inertia estimator change time load / J_est t load
Access level: 3 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
5.00 [ms] 5000.00 [ms] 10.00 [ms]
p1563[0...n] CO: Mom. of inertia estimator load torque direction of rotation pos. / J_est M pos
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: p2003 Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
-340.28235E36 [Nm] 340.28235E36 [Nm] 0.00 [Nm]
p1564[0...n] CO: Mom. of inertia estimator load torque direction of rotation neg. / J_est M neg
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: p2003 Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
-340.28235E36 [Nm] 340.28235E36 [Nm] 0.00 [Nm]