2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
266 List Manual (LH11), 01/2016, A5E33839529
Description: Displays the stator inductance identified for the 4th point of the saturation characteristic.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the identified IGBT threshold voltage.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays the identified effective valve lockout time.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Displays identified rotor resistance (on separately excited synchronous motors: damping resistance).
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Description: Sets the configuration of the rotating measurement.
For bit 12 = 1:
The selection only has an effect on the measurement p1960 = 1, 2. For the shortened measurement, the magnetizing
current and moment of inertia are determined with a somewhat lower accuracy.
r1919[0...2] Identified stator inductance 4 / L_stator 4 ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [mH] - [mH] - [mH]
r1925[0...2] Identified threshold voltage / U_threshold ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1926[0...2] Identified effective valve lockout time / t_lock_valve id
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [µs] - [µs] - [µs]
r1927[0...2] Identified rotor resistance / R_rotor ident
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [ohm] - [ohm] - [ohm]
p1959[0...n] Rotating measurement configuration / Rot meas config
PM230
PM230_STO
PM240
Access level: 3 Calculated: p0340 = 1 Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: DDS, p0180
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 0000 0001 1110 bin

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals