SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
451
2 Parameters
2.2 List of parameters
Notice: Before switching off the Control Unit, ensure that the system logbook is switched out (p9930[0] = 0).
If writing to the file is activated (p9930[2] = 1), writing to the file must be de-activated again before switching off the
Control Unit (p9930[2] = 0) in order to ensure that the system logbook has been completely written to the file.
Description: Only for service purposes.
Description: Only for service purposes.
Description: Display and binector output for a delay after POWER ON.
After switch-on, binector output r9935.0 is set with the start of the first sampling time and is again reset after approx.
100 ms.
Description: Displays the measured system utilization.
The higher the value displayed, the higher the system utilization.
Index: [0] = Computing time utilization (min)
[1] = Computing time utilization (averaged)
[2] = Computing time utilization (max)
[3] = Largest total utilization (min)
[4] = Largest total utilization (averaged)
[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency: Refer to: r9976
Refer to: F01054, F01205
Note: For index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
p9931[0...179] System logbook module selection / SYSLOG mod select.
Access level: 4 Calculated: - Data type: Unsigned32
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
p9932 Save system logbook EEPROM / SYSLOG EEPROM save
Access level: 4 Calculated: - Data type: Unsigned8
Can be changed: U, T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 255 0
r9935.0 BO: POWER ON delay signal / POWER ON t_delay
Access level: 4 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 POWER ON delay signal High Low -
r9975[0...7] System utilization measured / Sys util meas
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [%] - [%] - [%]