2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
506 List Manual (LH11), 01/2016, A5E33839529
Index: [0] = Input X
[1] = Setting value SV
Description: Sets the upper limit value LU of instance INT 0 of the integrator.
Description: Sets the lower limit value LL of instance INT 0 of the integrator.
Description: Sets the integrating time constant Ti in milliseconds of instance INT 0 of the integrator.
Description: Sets the signal source for the "accept setting value" signal of instant INT 0 of the integrator.
Description: Display parameter for output quantity Y of instance INT 0 of the integrator.
If LL>= LU, then the output quantity Y = LU.
Description: Display parameter for the signal QU that output quantity Y of instance INT 0 of the integrator has reached the upper
limit value LU.
p20257 INT 0 upper limit value LU / INT 0 upper lim LU
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20258 INT 0 lower limit value LL / INT 0 lower lim LL
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20259 INT 0 integrating time constant in ms / INT 0 T_Integr ms
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
0.00 340.28235E36 0.00
p20260 BI: INT 0 accept setting value S / INT 0 acc set val
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - 0
r20261 CO: INT 0 output Y / INT 0 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - -
r20262 BO: INT 0 integrator at the upper limit QU / INT 0 QU
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - -