SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
421
2 Parameters
2.2 List of parameters
Description: Sets the time interval for monitoring the forced checking procedure and testing the Safety switch-off signal paths for
STO via terminals on the Power Module.
Within the parameterized time, STO must have been de-selected at least once.
Dependency: Refer to: r9662
Refer to: A01678
Note: STO: Safe Torque Off
Description: Displays the remaining time for monitoring the forced checking procedure and testing the Safety switch-off signal
paths for STO via terminals on the Power Module.
After the monitoring time set in p9661 has expired, an appropriate alarm is output.
Dependency: Refer to: p9661
Refer to: A01678
Note: PM: Power Module
STO: Safe Torque Off
Description: CRC via Node Identifier of the Control Unit.
Note: CU: Control Unit
p9661 SI forced checking procedure STO via PM terminals time / FCP_dyn STO PM-T t
PM240
PM250
PM260
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [h] 9000.00 [h] 8.00 [h]
r9662 SI forced checking procedure STO via PM terminals remaining time /
FCP_dyn STO PM-T t
PM240
PM250
PM260
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [h] - [h] - [h]
p9670 SI module identification Control Unit / Module ID CU
PM230_STO
PM240
PM250
PM260
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 4294967295 0

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals