SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
371
2 Parameters
2.2 List of parameters
Description: Displays the PROFIenergy mode ID of the effective energy-saving mode.
Value: 0: POWER OFF
2: Energy-saving mode 2
240: Operation
255: Ready
Note: Pe: PROFIenergy profiles
Description: Sets the minimum possible pause time for the energy-saving mode.
The value is the sum of the following times:
- Energy-saving mode transition time
- Operating state transition time regular
- Energy-saving mode, time of minimum stay
Index: [0] = Reserved
[1] = Mode 2
Note: It is not permissible that the value is less than the sum of the "energy-saving mode transition time" and the "operating
state transition time" (system properties).
Pe: PROFIenergy profiles
Description: Sets the time of maximum stay for the energy-saving mode.
Index: [0] = Reserved
[1] = Mode 2
Note: Pe: PROFIenergy profiles
Description: Sets the general properties for energy-saving.
r5600 Pe energy-saving mode ID / Pe mode ID
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381, 2382
Min Max Factory setting
0 255 -
p5602[0...1] Pe energy-saving mode pause time minimal / Pe mod t_pause min
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381
Min Max Factory setting
300000 [ms] 4294967295 [ms] [0] 300000 [ms]
[1] 480000 [ms]
p5606[0...1] Pe energy-saving mode time of maximum stay / Pe t_max_stay
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381
Min Max Factory setting
0 [ms] 4294967295 [ms] 4294967295 [ms]
p5611 Pe energy-saving properties general / Pe properties gen
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381, 2382
Min Max Factory setting
- - 0000 bin

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals