2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
498 List Manual (LH11), 01/2016, A5E33839529
Description: Sets the signal source of the switch setting I of instance BSW 1 of the binary changeover switch.
Description: Display parameter for output quantity Q of instance BSW 1 of the binary changeover switch.
Description: Setting parameter for the run-time group in which the instance BSW 1 of the binary changeover switch is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance BSW 1 within the run-time group set in p20216.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 0 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
p20214 BI: BSW 1 switch setting I / BSW 1 sw_setting
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
r20215 BO: BSW 1 output Q / BSW 1 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - -
p20216 BSW 1 run-time group / BSW 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
1 9999 9999
p20217 BSW 1 run sequence / BSW 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
0 7999 590
p20218[0...1] CI: NSW 0 inputs / NSW 0 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals