EasyManuals Logo

Siemens CU240B-2 List Manual

Siemens CU240B-2
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #493 background imageLoading...
Page #493 background image
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
493
2 Parameters
2.2 List of parameters
Description: Display parameter for output Q of instance RSR 0 of the RS flipflop
Description: Display parameter for inverted output QN of instance RSR 0 of the RS flipflop.
Description: Setting parameter for the run-time group in which instance RSR 0 of the RS flipflop is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance RSR 0 within the run-time group set in p20191.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for set input S and reset input R of instance RSR 1 of the RS flipflop.
Index: [0] = Set S
[1] = Reset R
r20189 BO: RSR 0 output Q / RSR 0 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -
r20190 BO: RSR 0 inverted output QN / RSR 0 inv outp QN
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - -
p20191 RSR 0 run-time group / RSR 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
1 9999 9999
p20192 RSR 0 run sequence / RSR 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
0 7999 520
p20193[0...1] BI: RSR 1 inputs / RSR 1 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7240
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals