2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
378 List Manual (LH11), 01/2016, A5E33839529
Description: Displays the sampling times currently present on the drive unit.
r7901[0...63]: sampling times of hardware time slices.
r7901[64...82]: sampling times of software time slices.
r7901[x] = 0, means the following:
No methods have been registered in the time slice involved.
Note: The basis for the software time slices is T_NRK = p7901[13].
Description: Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by OA applications such as DCC or FBLOCKS.
Note: OA: Open Architecture
Description: For the manual mode: Display of STW1 (control word 1) entered at the BOP/ IOP.
Description: For the manual mode: Display of the speed setpoint entered at the BOP/ IOP.
r7901[0...81] Sampling times / t_sample
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [µs] - [µs] - [µs]
r7903 Hardware sampling times still assignable / HW t_samp free
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r8540.0...15 BO: STW1 from BOP/IOP in the manual mode / STW1 OP
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 ON/OFF1 Yes No -
01 OC / OFF2 Yes No -
02 OC / OFF3 Yes No -
03 Reserved Yes No -
04 Reserved Yes No -
05 Reserved Yes No -
06 Reserved Yes No -
07 Acknowledge fault Yes No -
08 Jog bit 0 Yes No 3030
09 Jog bit 1 Yes No 3030
10 Reserved Yes No -
11 Direction reversal (setpoint) Yes No -
12 Reserved Yes No -
13 Reserved Yes No -
14 Reserved Yes No -
15 Reserved Yes No -
r8541 CO: Speed setpoint from BOP/IOP in the manual mode / N_set OP
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Unit group: 3_1 Unit selection: p0505 Func. diagram: -
Min Max Factory setting
- [rpm] - [rpm] - [rpm]

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals