Technicalspecications
Powerspecications
ThissectionprovidesthetechnicalspecicationsandrequirementsrelatedtotheAC
and/orDCmainssupply.
Colourdisplay
•ThecolourdisplayisnotapartoftheSimradSU90scopeofsupply.Refertothe
documentationprovidedbythemanufacturer.
ProcessorUnit
•Voltagerequirement:115/230Vac/47–63Hz/singlephase,selectable(nominal)
•Maximumvoltagedeviation:15%
•Maximumtransient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:Approximately150VA
Audioamplierwithloudspeakers
Notapplicable.Refertothedocumentationprovidedbythemanufacturer.
Operatingpanel
Notapplicable.ThisunitisnotpoweredbyACmains.
TransceiverUnit
•Voltagerequirement:230Vac/47–63Hz/singlephase
•Maximumvoltagedeviation:15%
•Maximumtransient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:Approximately600VA
HullUnit
•Voltagerequirement:230/380/440Vac/47–63Hz/3–phase
•Maximumvoltagedeviation,230Vac:15%
•Maximumvoltagedeviation,380/440Vac:340to485Vac
•Maximumtransient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:Approximately3000VA
Environmentalspecications
Thissectionprovidesthetechnicalspecicationsandrequirementsrelatedtothe
environmentalconditions.
Referencestandards
•IEC60945
•EMCNoiseemission:EN61000-6-4
•EMCNoiseimmunity:EN61000-6-2