Simrad SU90 - Sonar Room Requirements; Watertight Integrity

Simrad SU90
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SimradSU90
Sonarroomrequirements
The“sonarroom”isthecompartmentinwhichtheTransceiverUnitandthehullunit
areinstalled.
ObservetheseminimumrequirementstoobtainsuitableworkingconditionsforSimrad
SU90installation,useandmaintenance.
Itisstronglyrecommendedtouseadedicatedcompartmenttohousethehullunitandthe
TransceiverUnit.Thesetwounitsmustalsobeinstalledrelativelyclosetoeachother
duetothelimitedlengthofthetransducercables.
Topics
Watertightintegrityonpage42
Sizeandaccessonpage43
Heatingonpage43
Insulationonpage43
Ventilationonpage43
Cableprotectiononpage44
Electricalinstallationsandlightsonpage44
Bilgepumpanddeckingonpage44
Liftingdeviceonpage44
Communicationonpage44
Watertightintegrity
Thesize,locationanddesignofthesonarroommustfullallrequirementstothe
vessel’swatertightintegrity.Intheeventofamajorleakinthesonarroom,itmustbe
possibletocloseallwatertighthatchesand/ordoorstothesonarroomtomaintainthe
vesselstabilityandsafety.
Thephysicalsizeofthesonarroommustbelimited,sothatintheeventofamajor
leak,theoodingofthesonarroomwillnotinduceinstability,orcausethevesselto
capsizeorsink.
Ensurethatallwatertightdecksandbulkheadsareinspectedperiodicallytoverifythat
therearenounprotectedopeningsorimproperpenetrationsthatwillallowprogressive
oodingfromthesonarroom,andthatthewatertightdoorsandhatchesareinplaceand
inworkingorder.
Ensurebilgehighlevelalarmsarearrangedtoprovidetheearliestwarningsofabnormal
accumulation.Thehighlevelbilgealarmsmustbesetaslowaspossibletothedeck
orbilgewellandpositionedalongthecentreareaofthecompartmentorinalocation
atwhichtheuidswillgravitatetorst.
Allcablesleadinginandoutofthesonarroommustberuninsteelconduits.Thesesteel
conduitsmustreachupandabovethefreeboarddeck.
42
381293/A